Hydraulic
Oil Unit
In order to operate various hydraulic valves in chemical plants, so called hydraulic power units, back-up stations and field manifolds are necessary. BHDT offers complete systems as per various licensor requirements for complete chemical plants.
Main Features
- Ex-Certification: ATEX, FM, IECEx, NEC, CEC, GOST, CNEx
- Tank Volume: V= up to 10000 [L] (Design rectangular) (With or without oil sump)
- Tank Material: SS (not painted) or CS (painted)
- Piston Accumulator Material (Body): SS (not painted) or CS (painted)
- Nitrogen Buffer Material: SS (not painted) or CS (painted)
- Pumps: APP or Gear Pump 16 [ccm] - 360 [ccm] / 9 [kW] - 250 [kW]
- Flow: Q = 24 [l/min] - 540 [l/min]
- Operating Pressure: p = 150 - 180 [bar-g]
- Design Temperature: -50 to 80 [°C]
- Visual Instrumentation: Gauges
- Monitoring Instrumentation: Electrical transmitters deliver a 4-20 [mA] signal divers protocols
- Design Code: ASME Sect. VIII Div.1 (incl. U stamp) or DIN / PED (incl. CE Marking) / GOST / CML